sane-coolscan 5 "13 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
sane-coolscan
NAME
sane-coolscan - SANE backend for Nikon film-scanners
ABOUT THIS FILE
This file is a short description of the coolscan backend for
SANE .
DESCRIPTION
The
sane-coolscan library implements a SANE backend that provides the interface to the following Nikon
Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000.
Even though the backend has worked for a number of people, there are still some problems, especially in combination with some SCSI
card/
drivers (
AHA-1505/
aha152x.o)
and the autofocus command.
You should consider this backend 'alpha' and be careful when using it the first time.
CONFIGURATION
The configuration file for this backend resides in
@CONFIGDIR@/coolscan.conf .
Its content is a list of device names that correspond to Nikon Coolscan scanners. Empty lines
and lines starting with a hash mark (#) are ignored. A sample configuration file is
shown below:
#scsi Vendor Model Type
scsi Nikon * Scanner
/dev/scanner
The special device name must be a generic SCSI device or a symlink to such a device.
To find out to which device your scanner is assigned and how you can set the
permissions of that device, have a look at
sane-scsi (5).
SCSI ADAPTER TIPS
Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the
Coolscan scanners. These systems hang when the autofocus command is send to the Scanner.
To see a list of which
card/
driver combinations work or don't work have a look at:
http://andreas.rick.free.fr/sane/autofocus.html.
FILES
The backend configuration file:
@CONFIGDIR@/coolscan.conf
The static library implementing this backend:
@LIBDIR@/libsane-coolscan.a
The shared library implementing this backend:
@LIBDIR@/libsane-coolscan.so (present on systems that support dynamic loading)
ENVIRONMENT
SANE_DEBUG_COOLSCAN If the library was compiled with debug support enabled, this environment
variable controls the debug level for this backend. E.g., a value of 128
requests all debug output to be printed. Smaller levels reduce verbosity.
Examples:
On bash:
export SANE_DEBUG_COOLSCAN=8
On csh:
setenv SANE_DEBUG_COOLSCAN 8
BUGS
The autofocus command does not work with some SCSI
card/
driver combinations.
The gamma table is not implemented for the LS1000 yet.
The dust-removal is not working yet.
SEE ALSO
sane (7), sane-scsi (5)
http://andreas.rick.free.fr/sane/ The homepage of this backend.
http://www.sema.be/coolscan/ The original version of the coolscan backend by Didier.
THANKS TO
Didier Carlier - For writing the original Coolscan backend (without it I would not have started this).
Oliver Rauch - For adapting xsane so quickly to the infrared stuff.
All the other people working on SANE.
AUTHOR
Andreas Rick
EMAIL-CONTACT
andreas.rick@free.fr