162306a36Sopenharmony_ci/* 262306a36Sopenharmony_ci** HP VISUALIZE Workstation PCI Bus Defect 362306a36Sopenharmony_ci** 462306a36Sopenharmony_ci** "HP has discovered a potential system defect that can affect 562306a36Sopenharmony_ci** the behavior of five models of HP VISUALIZE workstations when 662306a36Sopenharmony_ci** equipped with third-party or customer-installed PCI I/O expansion 762306a36Sopenharmony_ci** cards. The defect is limited to the HP C180, C160, C160L, B160L, 862306a36Sopenharmony_ci** and B132L VISUALIZE workstations, and will only be encountered 962306a36Sopenharmony_ci** when data is transmitted through PCI I/O expansion cards on the 1062306a36Sopenharmony_ci** PCI bus. HP-supplied graphics cards that utilize the PCI bus are 1162306a36Sopenharmony_ci** not affected." 1262306a36Sopenharmony_ci** 1362306a36Sopenharmony_ci** http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp?locale=en_US&prodTypeId=12454&prodSeriesId=44443 1462306a36Sopenharmony_ci** 1562306a36Sopenharmony_ci** Product First Good Serial Number 1662306a36Sopenharmony_ci** C200/C240 (US) US67350000 1762306a36Sopenharmony_ci**B132L+/B180 (US) US67390000 1862306a36Sopenharmony_ci** C200 (Europe) 3713G01000 1962306a36Sopenharmony_ci** B180L (Europe) 3720G01000 2062306a36Sopenharmony_ci** 2162306a36Sopenharmony_ci** Note that many boards were fixed/replaced under a free replacement 2262306a36Sopenharmony_ci** program. Assume a machine is only "suspect" until proven otherwise. 2362306a36Sopenharmony_ci** 2462306a36Sopenharmony_ci** "The pci_check program will also be available as application 2562306a36Sopenharmony_ci** patch PHSS_12295" 2662306a36Sopenharmony_ci*/ 2762306a36Sopenharmony_ci 28