162306a36Sopenharmony_ciWhat:		/sys/class/power_supply/ltc4162-l/charge_status
262306a36Sopenharmony_ciDate:		Januari 2021
362306a36Sopenharmony_ciKernelVersion:	5.11
462306a36Sopenharmony_ciDescription:
562306a36Sopenharmony_ci		Detailed charge status information as reported by the chip.
662306a36Sopenharmony_ci
762306a36Sopenharmony_ci		Access: Read
862306a36Sopenharmony_ci
962306a36Sopenharmony_ci		Valid values:
1062306a36Sopenharmony_ci			ilim_reg_active
1162306a36Sopenharmony_ci			thermal_reg_active
1262306a36Sopenharmony_ci			vin_uvcl_active
1362306a36Sopenharmony_ci			iin_limit_active
1462306a36Sopenharmony_ci			constant_current
1562306a36Sopenharmony_ci			constant_voltage
1662306a36Sopenharmony_ci			charger_off
1762306a36Sopenharmony_ci
1862306a36Sopenharmony_ciWhat:		/sys/class/power_supply/ltc4162-l/ibat
1962306a36Sopenharmony_ciDate:		Januari 2021
2062306a36Sopenharmony_ciKernelVersion:	5.11
2162306a36Sopenharmony_ciDescription:
2262306a36Sopenharmony_ci		Battery input current as measured by the charger. Negative value
2362306a36Sopenharmony_ci		means that the battery is discharging.
2462306a36Sopenharmony_ci
2562306a36Sopenharmony_ci		Access: Read
2662306a36Sopenharmony_ci
2762306a36Sopenharmony_ci		Valid values: Signed value in microamps
2862306a36Sopenharmony_ci
2962306a36Sopenharmony_ciWhat:		/sys/class/power_supply/ltc4162-l/vbat
3062306a36Sopenharmony_ciDate:		Januari 2021
3162306a36Sopenharmony_ciKernelVersion:	5.11
3262306a36Sopenharmony_ciDescription:
3362306a36Sopenharmony_ci		Battery voltage as measured by the charger.
3462306a36Sopenharmony_ci
3562306a36Sopenharmony_ci		Access: Read
3662306a36Sopenharmony_ci
3762306a36Sopenharmony_ci		Valid values: In microvolts
3862306a36Sopenharmony_ci
3962306a36Sopenharmony_ciWhat:		/sys/class/power_supply/ltc4162-l/vbat_avg
4062306a36Sopenharmony_ciDate:		Januari 2021
4162306a36Sopenharmony_ciKernelVersion:	5.11
4262306a36Sopenharmony_ciDescription:
4362306a36Sopenharmony_ci		Battery voltage, averaged over time, as measured by the charger.
4462306a36Sopenharmony_ci
4562306a36Sopenharmony_ci		Access: Read
4662306a36Sopenharmony_ci
4762306a36Sopenharmony_ci		Valid values: In microvolts
4862306a36Sopenharmony_ci
4962306a36Sopenharmony_ciWhat:		/sys/class/power_supply/ltc4162-l/force_telemetry
5062306a36Sopenharmony_ciDate:		Januari 2021
5162306a36Sopenharmony_ciKernelVersion:	5.11
5262306a36Sopenharmony_ciDescription:
5362306a36Sopenharmony_ci		To save battery current, the measurement system is disabled if
5462306a36Sopenharmony_ci		the battery is the only source of power. This affects all
5562306a36Sopenharmony_ci		voltage, current and temperature measurements.
5662306a36Sopenharmony_ci		Write a "1" to this to keep performing telemetry once every few
5762306a36Sopenharmony_ci		seconds, even when running on battery (as reported by the online
5862306a36Sopenharmony_ci		property, which is "1" when external power is available and "0"
5962306a36Sopenharmony_ci		when the system runs on battery).
6062306a36Sopenharmony_ci
6162306a36Sopenharmony_ci		Access: Read, Write
6262306a36Sopenharmony_ci
6362306a36Sopenharmony_ci		Valid values: 0 (disabled) or 1 (enabled)
6462306a36Sopenharmony_ci
6562306a36Sopenharmony_ciWhat:		/sys/class/power_supply/ltc4162-l/arm_ship_mode
6662306a36Sopenharmony_ciDate:		Januari 2021
6762306a36Sopenharmony_ciKernelVersion:	5.11
6862306a36Sopenharmony_ciDescription:
6962306a36Sopenharmony_ci		The charger will normally drain the battery while inactive,
7062306a36Sopenharmony_ci		typically drawing about 54 microamps. Write a "1" to this
7162306a36Sopenharmony_ci		property to arm a special "ship" mode that extends shelf life
7262306a36Sopenharmony_ci		by reducing the leakage to about 2.8 microamps. The chip will
7362306a36Sopenharmony_ci		remain in this mode (and no longer respond to I2C commands)
7462306a36Sopenharmony_ci		until some external power-supply is attached raising the input
7562306a36Sopenharmony_ci		voltage above 1V. It will then automatically revert to "0".
7662306a36Sopenharmony_ci		Writing a "0" to the property cancels the "ship" mode request.
7762306a36Sopenharmony_ci		The ship mode, when armed, activates once the input voltage
7862306a36Sopenharmony_ci		drops below 1V.
7962306a36Sopenharmony_ci
8062306a36Sopenharmony_ci		Access: Read, Write
8162306a36Sopenharmony_ci
8262306a36Sopenharmony_ci		Valid values: 0 (disable) or 1 (enable)
83