162306a36Sopenharmony_ciWhat: /sys/bus/iio/devices/iio:deviceX/sensor_max_range 262306a36Sopenharmony_ciDate: January 2017 362306a36Sopenharmony_ciKernelVersion: 4.11 462306a36Sopenharmony_ciContact: linux-iio@vger.kernel.org 562306a36Sopenharmony_ciDescription: 662306a36Sopenharmony_ci Show or set the maximum range between the sensor and the 762306a36Sopenharmony_ci first object echoed in meters. Default value is 6.020. 862306a36Sopenharmony_ci This setting limits the time the driver is waiting for a 962306a36Sopenharmony_ci echo. 1062306a36Sopenharmony_ci 1162306a36Sopenharmony_ci Showing the range of available values is represented as the 1262306a36Sopenharmony_ci minimum value, the step and the maximum value, all enclosed 1362306a36Sopenharmony_ci in square brackets. 1462306a36Sopenharmony_ci 1562306a36Sopenharmony_ci Example:: 1662306a36Sopenharmony_ci 1762306a36Sopenharmony_ci [0.043 0.043 11.008] 18