162306a36Sopenharmony_ciWhat:		/sys/bus/iio/devices/iio:deviceX/ac_excitation_en
262306a36Sopenharmony_ciKernelVersion:
362306a36Sopenharmony_ciContact:	linux-iio@vger.kernel.org
462306a36Sopenharmony_ciDescription:
562306a36Sopenharmony_ci		This attribute, if available, is used to enable the AC
662306a36Sopenharmony_ci		excitation mode found on some converters. In ac excitation mode,
762306a36Sopenharmony_ci		the polarity of the excitation voltage is reversed on
862306a36Sopenharmony_ci		alternate cycles, to eliminate DC errors.
962306a36Sopenharmony_ci
1062306a36Sopenharmony_ciWhat:		/sys/bus/iio/devices/iio:deviceX/bridge_switch_en
1162306a36Sopenharmony_ciKernelVersion:
1262306a36Sopenharmony_ciContact:	linux-iio@vger.kernel.org
1362306a36Sopenharmony_ciDescription:
1462306a36Sopenharmony_ci		This attribute, if available, is used to close or open the
1562306a36Sopenharmony_ci		bridge power down switch found on some converters.
1662306a36Sopenharmony_ci		In bridge applications, such as strain gauges and load cells,
1762306a36Sopenharmony_ci		the bridge itself consumes the majority of the current in the
1862306a36Sopenharmony_ci		system. To minimize the current consumption of the system,
1962306a36Sopenharmony_ci		the bridge can be disconnected (when it is not being used
2062306a36Sopenharmony_ci		using the bridge_switch_en attribute.
2162306a36Sopenharmony_ci
2262306a36Sopenharmony_ciWhat:		/sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration
2362306a36Sopenharmony_ciKernelVersion:
2462306a36Sopenharmony_ciContact:	linux-iio@vger.kernel.org
2562306a36Sopenharmony_ciDescription:
2662306a36Sopenharmony_ci		Initiates the system calibration procedure. This is done on a
2762306a36Sopenharmony_ci		single channel at a time. Write '1' to start the calibration.
2862306a36Sopenharmony_ci
2962306a36Sopenharmony_ciWhat:		/sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw
3062306a36Sopenharmony_ciKernelVersion:
3162306a36Sopenharmony_ciContact:	linux-iio@vger.kernel.org
3262306a36Sopenharmony_ciDescription:
3362306a36Sopenharmony_ci		Measure voltage from AIN2 pin connected to AIN(+)
3462306a36Sopenharmony_ci		and AIN(-) shorted.
3562306a36Sopenharmony_ci
3662306a36Sopenharmony_ciWhat:		/sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available
3762306a36Sopenharmony_ciKernelVersion:
3862306a36Sopenharmony_ciContact:	linux-iio@vger.kernel.org
3962306a36Sopenharmony_ciDescription:
4062306a36Sopenharmony_ci		Reading returns a list with the possible calibration modes.
4162306a36Sopenharmony_ci		There are two available options:
4262306a36Sopenharmony_ci		"zero_scale" - calibrate to zero scale
4362306a36Sopenharmony_ci		"full_scale" - calibrate to full scale
4462306a36Sopenharmony_ci
4562306a36Sopenharmony_ciWhat:		/sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode
4662306a36Sopenharmony_ciKernelVersion:
4762306a36Sopenharmony_ciContact:	linux-iio@vger.kernel.org
4862306a36Sopenharmony_ciDescription:
4962306a36Sopenharmony_ci		Sets up the calibration mode used in the system calibration
5062306a36Sopenharmony_ci		procedure. Reading returns the current calibration mode.
5162306a36Sopenharmony_ci		Writing sets the system calibration mode.