18c2ecf20Sopenharmony_ci* Melexis MLX90632 contactless Infra Red temperature sensor
28c2ecf20Sopenharmony_ci
38c2ecf20Sopenharmony_ciLink to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
48c2ecf20Sopenharmony_ci
58c2ecf20Sopenharmony_ciThere are various applications for the Infra Red contactless temperature sensor
68c2ecf20Sopenharmony_ciand MLX90632 is most suitable for consumer applications where measured object
78c2ecf20Sopenharmony_citemperature is in range between -20 to 200 degrees Celsius with relative error
88c2ecf20Sopenharmony_ciof measurement below 1 degree Celsius in object temperature range for
98c2ecf20Sopenharmony_ciindustrial applications. Since it can operate and measure ambient temperature
108c2ecf20Sopenharmony_ciin range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
118c2ecf20Sopenharmony_ci
128c2ecf20Sopenharmony_ciBe aware that electronics surrounding the sensor can increase ambient
138c2ecf20Sopenharmony_citemperature. MLX90632 can be calibrated to reduce the housing effect via
148c2ecf20Sopenharmony_cialready existing EEPROM parameters.
158c2ecf20Sopenharmony_ci
168c2ecf20Sopenharmony_ciSince measured object emissivity effects Infra Red energy emitted, emissivity
178c2ecf20Sopenharmony_cishould be set before requesting the object temperature.
188c2ecf20Sopenharmony_ci
198c2ecf20Sopenharmony_ciRequired properties:
208c2ecf20Sopenharmony_ci  - compatible: should be "melexis,mlx90632"
218c2ecf20Sopenharmony_ci  - reg: the I2C address of the sensor (default 0x3a)
228c2ecf20Sopenharmony_ci
238c2ecf20Sopenharmony_ciExample:
248c2ecf20Sopenharmony_ci
258c2ecf20Sopenharmony_cimlx90632@3a {
268c2ecf20Sopenharmony_ci	compatible = "melexis,mlx90632";
278c2ecf20Sopenharmony_ci	reg = <0x3a>;
288c2ecf20Sopenharmony_ci};
29