Lines Matching refs:vddio
1282 * according to voltage of vdda and vddio
1283 * 3. line out VAG, normally set to vddio/2
1287 * 2. vdda and vddio voltage value. > 3.1v or not
1293 int vddio;
1304 vddio = regulator_get_voltage(sgtl5000->supplies[VDDIO].consumer);
1310 vddio = vddio / 1000;
1313 if (vdda <= 0 || vddio <= 0 || vddd < 0) {
1320 if (vdda > 3600 || vddio > 3600 || vddd > 1980) {
1322 "exceed max voltage vdda %dmV vddio %dmV vddd %dmV\n",
1323 vdda, vddio, vddd);
1335 if (vddio < 3100 && vdda < 3100) {
1345 * if vddio == vdda the source of charge pump should be
1376 /* set line out VAG to vddio / 2, in range (0.8v, 1.675v) */
1377 lo_vag = vddio / 2;